Solutions

SIMPLE OR COMPLEX,
STANLY IS READY FOR IT

Over the years, Stanly delivered various projects from a single standby genset to complex multiple genset projects with sophisticated engineering and flawless implementation.
Applications
Prime Power Genset
Single generator set operating manually or remotely in locations with no power from the grid.
Mains uptime
     
Power Range
     
Uptime
     
Dual Mutual
Two gensets work as backup for each other as well as redistribute the working hours between them, leading to high availability and fewer service visits.
Mains uptime
     
Power Range
     
Uptime
     
Auto Mains Failure
The generator monitors the electrical grid power and in the event of its failure. It will start and transfer the load to the generator. When the Mains return, the power will be switched back to the Mains and the generator will shutdown after cooling down.
Mains uptime
     
Power Range
     
Uptime
     
Critical load AMF
Similar to Auto Mains Failure with added UPS for critical loads, and similar to Data center Tier 1.
Mains uptime
     
Power Range
     
Uptime
     
Dual Mutual Standby
When the Electrical grid is unstable, a single genset will run almost constantly which is not ideal for critical loads as any genset maintenance or downtime may result in power outage. To increase the reliability of the system, two gensets work as backup for each other in addition to redistribute the working hours between them. leading to high availability and fewer service visits.
Mains uptime
     
Power Range
     
Uptime
     
Multiple Gensets in Parallel
Up to 32 gensets synced together to act as a single source of electricity. Generators communicate with each other to match the load demand . When the load increases, more gensets are requested to start and sync. Or shutdown when the load decreases.
Mains uptime
     
Power Range
     
Uptime
     
Hybrid DC Generator
Hybrid system for off grid telecom sites offer huge fuel saving in addition to longer generator service visits and life expectancy. DC generator can be equipped with multiple battery configurations and sizes optimized to site conditions and cost for a complete power module including advanced battery charging and remote monitoring capability.
Mains uptime
     
Power Range
     
Uptime
     
Data Center Power Solutions
When up-time is the most critical aspect, this system has an uptime of 99.995% and should be fully fault tolerant.
Mains uptime
     
Power Range
     
Uptime
     